============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 807 MODEL: TR-2400 SUBJECT: OPTIONAL CHARGE INPUT PROTECTION Some users may request addition of a series diode to the Charge Jack to prevent inadvertent shorting of the battery pack if a voltmeter probe, headphone jack, or other conductor accidentally shorts across the external Charge Jack. This can be used only for the standard wall charger. The optional fast chargers require battery voltage be available at the charge jack as feedback to the charqer requlator. Add a Si diode in series with the battery charge line, at the Charge Jack. Observe battery polarity. Charging current will drop approximately 2 ma. 1. Si diode must be rated at least 200mA. 2. Install carefully-don't short the YELLOW B+ lead when reassembling.