============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 1019 MODEL: TS-950 SUBJECT: Low Power Output after Temp. Protection Symptom: After transmitting for approximately 2 hours at 50% duty with 150 watts output the temperature protection circuit activates reducing the output power to about 50 watts. Normally, full output power will be restored after the fans have had a chance to cool things down. Occasionally the power output will not return to normal, even after extended receive operations. Cause: The temperature sensor is attached to the main transformer and is set to activate at 80 degrees C. This setting was selected to reduce power before the internal fuse on the transformer opens. Corrective Action: After thorough testing, we have found that the temperature sensor should be set to 90 deg C to allow proper return to full power transmit. This setting will also allow the radio to be used at higher ambient room temperatures without worrying about the power output dropping in the middle of a QSO. Replace S1 the temperature sensor. Parts Required: Qty Description Kenwood Part No. Circuit Description 1 90 deg C Thermal switch S59-1416-05 S1 Caution: This modification requires soldering equipment rated for CMOS type circuits. It also requires familiarity with surface mount soldering techniques. If you do not have the proper equipment or knowledge do not attempt this modification yourself. Seek qualified assistance. Time required for this modification is 30 minutes or less. Service code A:93 B:20 C:S1 D:91