RACAL INSTRUMENTS LTD


PRELIMINARY RELEASE NOTE



Digital Radio Product Support Group

6111 software version 3.02G

This software version is for users of Ericsson BTSs only. This software can be used to 
configure the semi permanent links in the TRI, after which the BTS may be tested in the 
normal way.

There is no requirement for a connection to a BSC.
There is no requirement for a Line Interface Test Adaptor (LIFTA card).

SOFTWARE INSTALLATION:

Create a new directory on your PC, e.g. C:\TRI
Install the software to this directory in the usual way i.e. 
A:> INSTALL C:\TRI

After installation, you must create three sub-directories under your main MMI directory.
 These directories are listed on the release disk.

This directory structure and the files within each directory must be copied exactly 
from the release disk.  It is best to use the XCOPY DOS command with the 
delimiter /S to ensure that the directory structure remains the same.

 
PREPARATION FOR USE:

Setting up the A-bis Mapping Table:

Please refer to the attached notes for details of  A-bis mapping requirements.


Connections:

The A-bis connectors on the test set may be connected to either the two BNC connectors
 on top of the BTS cabinet, or directly to the ETB0 card in place of the BSC connection.


Testing:

The CONFIGURE TRI test should then be selected from the Functional Test Menu. 
The parameters for the CONFIGURE TRI test are as follows:
  
Download TRI code  (for this release - must be YES)
Set EMRP address   (for this release - set to 0)

If the red LED beneath the EMRP address header on the TRI is not flashing, the TRI 
should be reset before testing is started.

If you have any problems loading or running this software, please contact:

Peter Rowson
Digital Radio Product Support Group
Racal Instruments Limited
480 Bath Rd., Slough
Berks U.K.

Tel: +44 628 604455    Fax: +44 628 662017



23.12.93

NOTES ON USING THE TRI CONTROL SOFTWARE - (ref. 2410)


Note that the TRI control software will only be accessible if the Enhanced A-bis 
Capability (Option 57) is fitted and the TRI software (Option 225) is enabled in the 
6111/5.  For further information please consult the Digital Radio Support Group.  


Setting up of the A-bis mapping table

Before the TRI is configured, it is necessary to set up the A-bis Mapping table to 
provide the necessary information to the 6111 to set up the TRI Semi-permanent 
connections.  This should be performed as detailed below.

The A-bis mapping table should be set up for all the transceivers to be tested in the 
BTS.  This avoids having to re-run the Configure TRI test each time a new transceiver 
is to be tested.

The TEIs for the BCF (TGC) and each transceiver (TRX) should be set up in the 
normal way.  

The signalling timeslots for the transceivers (TRXs) should be selected as required to 
use a different timeslot for each TRX.  The signalling timeslot for the BCF should be 
set to be the same as that for the first transceiver to be tested.

The traffic timeslots should be selected as required to use two different slots for each 
transceiver.  The TRI should then be configured using the Configure TRI test.

Note that TRX 1, 2, 3 and 4 are automatically mapped by the 6111 in the TRI to 'Cell 
1' - RILT card 9(RTT 1).  

In the same way TRX 5, 6, 7 and 8 are mapped to 'Cell 2' - RILT 8, (RTT 2) etc.  
Thus if the BTS is set up to be 'Cell 3' using RILT card 7, (RTT 3) then TRX 
identifiers numbers 9 to 12 should be used in the A-bis mapping table.

Following testing on one transceiver, this transceiver should be reset, using the Reset 
BTS test.  Then the signalling slot for the BCF in the A-bis mapping table should be 
changed to that of the next transceiver to be tested and the Configure BTS test should 
be run with the TRX identifier also changed to that of the next transceiver to be tested.  
Testing on the next transceiver can then be performed, and so on.

An example is given below of the A-bis mapping table for testing the second 
transceiver of 'Cell 2'.  (TRX 6)
 

	TEI	Signalling 
Slot	Traffic	Slots
BCF	58	5		
TRX 5	0	2	3	4
TRX 6	1	5	6	7
TRX 7	2	8	9	10
TRX 8	3	11	12	13

Note that changes to simplify the above procedure are being considered for future 
software releases.


Setting the PC code path for the TRI software

For TRI code download the MMI requires the files to be downloaded to be located in 
the directory structure shown below:

	    XXXXXX

		|____	REPER
		|		|___	EMRP
		|			   emgfdr
		|			   reper
		|			   teetr
		|
		|
		|____	RICSR
		|		|___	EMRP
		|			   ricsr
		|			   riltr
		|			
		|____	RITSR
				|___	EMRP
					   ritsr
					
					

The top level directory XXXXXX must be specified in the TRI Information menu 
option from the Parameters menu.

The files are in DOS binary format - as provided by Ericsson.

Connections to the TRI

Connections to and from the 6111/5 should be made to the ETBO card (RILT card 0) 
as this is the only ETB card supported at present.

Connections to and from the BTS should be made to the appropriate RTT card in the 
normal way.


Configuring the TRI

Select Configure TRI from the Tests/Functional Tests menu.

Select Code Download  - YES 
Set the EMRP value which has been strapped in the TRI - (usually 0)

Note that configuring a TRI which already has code downloaded is not yet available.

Testing can then continue in the normal way, by running the configure BTS test.