CT-302 (170-1051) NAM Programming
STEP 1 (Enter Program Mode):
Type: *3001#12345 9 Phone Responds: INSTALL
Type: Phone Responds: IDENTIF INFO PRI
Type: (see Note 1)
Note 1: If you wish to program the phone for a 2nd cellular phone
number, press BEFORE pressing . At this point the
phone will display "OPT INFO DISABLED". Now type: and
then . You may now continue with Step 2 as normal.
STEP 2 (Programming the Primary NAM information):
The phone will now inform you of the parameter it wants you to enter on
the top line with the previously programmed parameter (or factory
default) on second line. The starred (*) lines require information that
MUST be supplied by the cellular carrier.
Line 1 of Phone: HOME SYS Type: 5-digit Home System ID then
Line 1 of Phone: ACCESS Type: IF line 2 displays: 0 then
Line 1 of Phone: LOCL OPT Type: IF line 2 displays: 0 then
Line 1 of Phone: PHON Type: 10-digit phone number then
Line 1 of Phone: ST CLASS Type: 1 0 then
Line 1 of Phone: PAGING CH Type: 4-digit Paging Channel then
(Note: Channel A is: 0333,
Channel B is: 0334)
Line 1 of Phone: O-LOAD CLASS Type: 0 and last digit of phone # then
Line 1 of Phone: PREF SYS Type: to toggle between "A" and "B",
then (Note: A if Paging Ch is
0333, B if Paging Ch is 0334)
Line 1 of Phone: GROUP ID Type: 2-digit Group ID then
Line 1 of Phone: SECURITY Type: 5-digit Security Code then
Line 1 of Phone: SER NR Type: (Do NOT change this)
Line 1 of Phone: 1 DATE Type: (Do NOT change this)
Line 1 of Phone: 2 DATE Type: (todays) 6-digit date (in the form:
mmddyy), then
Line 1 of Phone: INSTALL Type:
The phone should now be correctly programmed.
Settings List: Accessories:
0 Lock Phone
1 Display Carrier Priority 17-605 Rapid Battery Charger
11 Change Carrier Priority (A/B) 17-607 Additional Battery
3 Display Time of Last Call 17-606 Mounting Kit and
33 Display Call Timer Total Power/External Antenna
44 Enable/Disable Key Entry Tone Adapter
5 Change Lock Code 39-08006 Handsfree Kit
6 Change Auto-Shutoff Time (Customer Order Only:
7 Change Primary/Secondary NAM 901-363-9260)
8 Clear Call Timers